High-Flex & High-Strength CCS Tracer Wire for Open Trench

  • 8AWG, 10AWG, 12AWG, 14AWG, 16AWG, 18AWG, 20AWG

  • 100feet, 500feet, 1000feet, 2500feet, 5000feet, other lengths are availabel upon request

  • plastic reel, wooden drum, pallet

  • 30KM

  • NINGBO, SHANGHAI 

  • T/T, L/C,

  • CE, RoHS, ISO9001, REACH

  • Normally 20 working days 

  • Open Trench / Open Cut

  • Copper Clad Steel

  • 30 mil/ 45 mil HDPE/ HMWPE

Availability:

tracer wire
Open Trench / Open Cut Tracer Wire

High-Flex & High-Strength CCS Tracer Wire for Open Trench

AITE Cable manufactures solid copper-clad steel tracer wire for open trench, open cut, plow-in, conduit and underground utility locating applications.

Choose High-Flex when easier handling and low recoil are important. Choose High-Strength when higher break load and stronger installation durability are required.

  • Solid CCS conductor
  • 21% IACS conductivity
  • HMWPE/HDPE insulation
  • 30 mil or 45 mil available
  • Direct burial rated
  • OEM color & marking

Choose the Right Open Trench Tracer Wire

High-Flex and High-Strength CCS tracer wire are both designed for open trench utility locating, but they solve different field installation problems.

Easy Handling

High-Flex CCS Tracer Wire

Designed for contractors who need easier bending, lower recoil and copper-like handling during installation.

  • Better flexibility during field installation
  • Easier routing, bending and connection
  • Suitable for open trench, plow-in, blow-in and conduit
  • Good choice for standard utility locating projects
Higher Break Load

High-Strength CCS Tracer Wire

Designed for projects requiring a stronger conductor and higher break load during installation and backfill.

  • Higher break load than High-Flex series
  • Better safety margin for longer open trench runs
  • Suitable for trenching, plowing and demanding burial conditions
  • Recommended when backfill conditions are more complex

High-Flex vs High-Strength

Series Main Purpose Recommended Use Not Ideal For
High-Flex CCS Easy handling, flexibility and low recoil Open trench, open cut, plow-in, blow-in, conduit and frequent bending High-pulling-force HDD or long-distance directional boring
High-Strength CCS Higher break load and improved durability Open trench main lines, trenching, plowing and demanding backfill conditions Extreme HDD pulling applications

Specification Overview

Product Type High-Flex & High-Strength CCS Tracer Wire
Application Open trench / open cut
Conductor Solid copper-clad steel
Conductivity 21% IACS
Insulation HMWPE/HDPE
Thickness 30 mil or 45 mil
Voltage Rating 30V or 600V
Burial Rating Direct burial rated
Customization Color, marking, spool length, packing

Wire Gauge and Break Load Options

Wire Gauge High-Flex Break Load High-Strength Break Load Insulation Thickness
18 AWG 75 lb 107 lb 30 mil / 45 mil
16 AWG 115 lb 144 lb 30 mil / 45 mil
14 AWG 194 lb 282 lb 30 mil / 45 mil
12 AWG 302 lb 452 lb 30 mil / 45 mil
10 AWG 513 lb 684 lb 30 mil / 45 mil
8 AWG 840 lb 30 mil / 45 mil

Other wire gauges, insulation thicknesses and break load requirements are available upon request.

Recommended Selection Guide

Project Condition Recommended Series
Standard open trench or open cut installation where easier handling is important High-Flex CCS Tracer Wire
Plow-in, blow-in, conduit or branch line installation with frequent bending High-Flex CCS Tracer Wire
Longer open trench runs or projects requiring higher break load High-Strength CCS Tracer Wire
More demanding backfill conditions or stronger installation durability required High-Strength CCS Tracer Wire
Horizontal directional drilling or trenchless boring Use Extra High-Strength CCS HDD Tracer Wire instead

30 mil and 45 mil insulation options are available according to project specification, burial condition and required protection level.

Tracer Wire Colors for Utility Identification

For North American utility projects, tracer wire insulation color is commonly selected by utility type, project specification, or APWA color code practice. AITE Cable can support custom insulation colors for OEM and project-specific requirements.

Color Typical Utility Application
Yellow Natural gas, oil, steam, petroleum, or hazardous material lines
Blue Water systems and potable water lines
Green Sanitary sewer, storm sewer, and drain lines
Orange Communication, cable television, fiber optic, alarm, or signal lines
Red Electrical power lines, cables, conduit, and lighting cables
Purple Reclaimed water, irrigation, or slurry lines
White Proposed excavation area or project marking
Black Custom or other applications based on project or engineer requirements

OEM customization is available for insulation color, wire marking, spool length, packaging, and private-label requirements.

OEM Customization and Packing

OEM Options

  • Custom insulation colors
  • Custom wire marking
  • Custom spool length
  • Private label packaging
  • Project-specific construction requirements

Packing Options

  • 500 ft spool
  • 1000 ft spool
  • 2500 ft spool
  • Plastic reel packing
  • Wooden drum packing available

Standards and Compliance

ASTM B910/B910M Copper-clad steel wire
ASTM B1010 Copper-clad steel wire physical properties
ASTM D1248 Polyethylene material
RoHS Compliance available
REACH Compliance available
ISO 9001:2015 Quality management system

FAQ

What is the difference between High-Flex and High-Strength?

High-Flex is easier to handle and has lower recoil. High-Strength provides higher break load and better durability during installation and backfill.

When should I choose High-Strength instead of High-Flex?

Choose High-Strength when the project requires higher break load, longer open trench runs or stronger durability during installation and backfill.

Is this product suitable for HDD?

For HDD or directional boring, Extra High-Strength CCS HDD Tracer Wire is recommended instead of standard open trench tracer wire.

Can AITE customize this tracer wire?

Yes. AITE Cable supports OEM color, wire marking, spool length, packing and project-specific requirements.

Request a Quote for Open Trench CCS Tracer Wire

Send your required wire gauge, High-Flex or High-Strength series, insulation thickness, voltage rating, color, marking, spool length, packing method and estimated quantity.

Email: info@at-cable.com
Website: www.at-cable.com

Previous: 
Next: 
Contact Us
Hangzhou Aite cable Co., Ltd. is a Chinese wire & cable manufacturer specializing in manufacturing Tracer Wire, Coaxial Cable, Lan Cable, Alarm Cable, Security Cable, Power Cable, Speaker cable, Audio Cable, CCTV Cable, Telephone Cable, and Cable Materials.

Products

Quick Links

Contact Us

Tel: +86-0571-61092020
Mob: +86 189 6802 3802
Add: No.556 Shangpan, Jinnan Subdistrict, Lin'an City, Hangzhou Zhejiang, China
Copyright © 2026 HANGZHOU AITE CABLE CO., LTD.. All rights reserved.